INDUSTRIAL · Latur, Maharashtra

Industrial & Commercial

Sheds, workshops, showrooms and plants — three-phase work planned around your production window, not ours.

01 / Scope

What we actually do on site.

1.1

Panel fabrication

Main and sub-distribution panels built to load schedule, with starters, contactors and overload protection.

1.2

Motor control

DOL and star-delta starters, VFD installation and interlocks for pumps, compressors and machine lines.

1.3

Cable management

Cable trays, conduit runs and busbar layouts routed for access and future expansion.

1.4

Power quality

Phase balancing, capacitor bank checks and voltage-drop measurement on long runs.

1.5

Shutdown planning

Staged work with defined isolation, so downtime is scheduled and short.

1.6

Thermal inspection

Periodic checks of joints and terminations to catch heating before it becomes a failure.

02 / Single-line

How the industrial circuit is drawn before it is built.

HT/LT incomerMain panelBus-barMCCBFeederStarter / VFDMotor loadcable tray run — power + control segregated

Cable trays route all feeder runs between panel and motor loads, sized with spare fill capacity

  1. HT / LT incomer — Utility or transformer
  2. Main panel — Bus-bar, metering
  3. MCCB — Feeder protection
  4. Starter / VFD — DOL, star-delta or drive
  5. Motor load — Pump, compressor, line

03 / Process

Planned around your production window.

  1. 01

    Load and utilisation study

    Machine-by-machine load list with duty cycles, so panels and cables are sized for how the plant actually runs.

    1–3 days·Machine load list with duty cycles

  2. 02

    Panel design

    Schedule and layout for main and sub-distribution boards, starters, VFDs and protection coordination.

    3–7 days·Panel general arrangement + protection schedule

  3. 03

    Shutdown plan

    Isolation points, staged sequence and the exact window agreed with your production team before work starts.

    Agreed before mobilisation·Written shutdown sequence and window

  4. 04

    Execution

    Panels, cable trays, conduit runs and busbar work installed to the layout, with access left for expansion.

    Scoped to the shutdown window·Installed panel and cable-tray runs

  5. 05

    Power quality check

    Phase balancing, capacitor bank verification and voltage-drop measurement on long runs.

    Half to full day·Power quality measurement report

  6. 06

    Thermal audit

    Joints and terminations imaged under load to catch heating before it becomes a failure.

    Half day, under normal load·Thermal image report with flagged joints

04 / Specification

What goes into the bill of materials, and why.

Main panel

Standard we specify

IP-rated sheet-steel enclosure, bus-bar sized to incomer rating with fault-current withstand

Why it matters

The main panel carries the full plant load; under-sizing the bus-bar is a fire risk under fault conditions.
Feeder protection

Standard we specify

Schneider / Legrand / Havells-class MCCB, selectively coordinated with upstream and downstream devices

Why it matters

Coordinated protection trips the nearest breaker to a fault, not the main incomer — keeps the rest of the plant running.
Motor starters

Standard we specify

DOL or star-delta starters, or VFDs, sized to motor FLC with thermal overload protection

Why it matters

An overload relay set to the wrong current either nuisance-trips or fails to protect the motor windings.
Cabling

Standard we specify

XLPE/PVC armoured power cable on galvanised cable trays, power and control segregated

Why it matters

Segregating power and control cabling avoids induced noise on sensor and PLC wiring.
Power factor correction

Standard we specify

Capacitor banks sized to measured reactive load, with detuned reactors where VFDs are present

Why it matters

Uncorrected power factor draws penalty charges from the DISCOM on a commercial connection.
Earthing

Standard we specify

IS 3043 earthing, separate pits for body earth and electronic/VFD earth

Why it matters

Mixing power and electronic earths on sensitive drive equipment causes nuisance faults and drive damage.

05 / Why us

Why industrial work goes wrong — and how we avoid it.

Downtime is scheduled, not discovered

Isolation and sequence are agreed in writing before anyone opens a panel, so the line restarts when we said it would.

Protection coordinated

Upstream and downstream devices selected together, so a fault trips the nearest breaker and not the main.

Built for the next machine

Spare ways, tray capacity and cable routes planned for the load you add next year.

06 / Continue the current

The rest of the spine.

01 / SOLAR

Solar Solutions

Rooftop generation designed against your actual load, not a brochure size.

See scope

02 / ELECTRICAL

Electrical Contracting

The spine of the building: wiring, distribution boards, earthing, protection.

See scope

04 / LIGHTING

Lighting Solutions & Maintenance

Lighting that is planned for lux and lifespan — and kept running after handover.

See scope

07 / Next step

A free survey, then honest numbers.

Tell us where you are and what you need. We come, we measure, and we quote what the building actually requires.