SOLAR · Latur, Maharashtra
Solar Solutions
We size a system against your actual consumption and your roof's real shading, then run the net-metering and subsidy files ourselves.
01 / Scope
What we actually do on site.
1.1
Load study and shading survey
Twelve-month consumption review plus on-site shadow logging, so the kW figure is earned rather than guessed.
1.2
System design and BOM
Single-line diagram, structure design for local wind loads, and an itemised bill of materials with make and rating.
1.3
Installation and commissioning
Mounting, DC and AC runs, inverter, protection and earthing — installed by our own team, not sublet.
1.4
Net metering and subsidy
DISCOM application, meter change, inspection coordination and the PM Surya Ghar claim followed until credit.
1.5
Monitoring
Baseline yield recorded at commissioning so under-generation is visible early, not a year later.
1.6
Cleaning and AMC
Scheduled panel cleaning and generation review, with response commitments in writing.
02 / Single-line
How the solar circuit is drawn before it is built.
Live AC/DC path in amber · isolators shown at every disconnect point
- PV array — ALMM-listed modules, series strings
- String inverter — MPPT, IEC 62109 protection
- AC combiner / isolators — Manual DC & AC disconnects
- Net meter — Bidirectional, DISCOM-sealed
- DISCOM grid — Export / import
- House load — Existing distribution board
03 / Process
Survey, design, install, net-metering, subsidy, AMC.
01
Survey
Roof measured, shading logged through the day, existing board and earthing inspected.
0.5–1 day on site·Shadow log + board condition note
02
Design
Load-calculated sizing, structure design for local wind loads and an itemised bill of materials.
2–4 days·Single-line diagram + itemised BOM
03
Install
Mounting, DC and AC runs, inverter, protection and earthing — executed by our own team.
2–5 days·Commissioned system, generation baseline recorded
04
Net metering
DISCOM application, meter change and inspection coordination until the bidirectional meter is live.
3–8 weeks (DISCOM-dependent)·Live bidirectional meter
05
Subsidy
PM Surya Ghar claim filed with ALMM-listed hardware references and followed until the bank credit lands.
Filed within days of commissioning·Subsidy claim tracked to bank credit
06
AMC
Cleaning schedule, generation review against the commissioning baseline, board thermal check.
Ongoing, scheduled visits·Written AMC with response times
04 / Specification
What goes into the bill of materials, and why.
| Item | Standard we specify | Why it matters |
|---|---|---|
| Modules | ALMM-listed panels, IEC 61215 / IEC 61730 certified | Keeps the subsidy file eligible and rules out cells that fail early in heat. |
| Inverter | IEC 62109 safety compliance, MPPT, written warranty terms named in the quote | The inverter is the part most likely to need service — the warranty terms matter more than the price. |
| DC cabling | IS 694 / IEC 62930 solar-grade DC cable, UV- and heat-resistant | Roof-run DC cable sees direct sun for years; ordinary house wire embrittles and cracks. |
| AC protection | Schneider / Legrand / Havells-class MCB, isolators and SPD at the AC combiner | Isolates the inverter safely for service and protects it from grid-side surges. |
| Earthing | IS 3043 earthing, dedicated pit for the array structure and inverter body | A leakage fault on an ungrounded array frame is a shock hazard, not just an inverter trip. |
| Mounting structure | Hot-dip galvanised structure rated for 120 kmph local wind class | Marathwada gets seasonal high winds; an under-rated structure is the most common failure on rooftops. |
| Net meter | DISCOM-approved bidirectional meter, sealed at commissioning | Export credit only accrues once the meter and paperwork are accepted by the DISCOM. |
- Modules
- ALMM-listed panels, IEC 61215 / IEC 61730 certified
- Keeps the subsidy file eligible and rules out cells that fail early in heat.
- Inverter
- IEC 62109 safety compliance, MPPT, written warranty terms named in the quote
- The inverter is the part most likely to need service — the warranty terms matter more than the price.
- DC cabling
- IS 694 / IEC 62930 solar-grade DC cable, UV- and heat-resistant
- Roof-run DC cable sees direct sun for years; ordinary house wire embrittles and cracks.
- AC protection
- Schneider / Legrand / Havells-class MCB, isolators and SPD at the AC combiner
- Isolates the inverter safely for service and protects it from grid-side surges.
- Earthing
- IS 3043 earthing, dedicated pit for the array structure and inverter body
- A leakage fault on an ungrounded array frame is a shock hazard, not just an inverter trip.
- Mounting structure
- Hot-dip galvanised structure rated for 120 kmph local wind class
- Marathwada gets seasonal high winds; an under-rated structure is the most common failure on rooftops.
- Net meter
- DISCOM-approved bidirectional meter, sealed at commissioning
- Export credit only accrues once the meter and paperwork are accepted by the DISCOM.
Standard we specify
Why it matters
Standard we specify
Why it matters
Standard we specify
Why it matters
Standard we specify
Why it matters
Standard we specify
Why it matters
Standard we specify
Why it matters
Standard we specify
Why it matters
05 / Why us
Why solar work goes wrong — and how we avoid it.
Sized on your bill, not a brochure
Twelve months of consumption and a real shadow log decide the kW figure. Oversizing sells; it does not pay back.
ALMM-listed hardware only
Modules and inverters from the approved list, named in the quote, so the subsidy file cannot be rejected on hardware.
The wiring gets checked first
Generation added to a weak board or untested earthing is how inverters die. We assess before we quote.
06 / Continue the current
The rest of the spine.
02 / ELECTRICAL
Electrical Contracting
The spine of the building: wiring, distribution boards, earthing, protection.
See scope03 / INDUSTRIAL
Industrial & Commercial
Three-phase installations for sheds, workshops, showrooms and plants.
See scope04 / LIGHTING
Lighting Solutions & Maintenance
Lighting that is planned for lux and lifespan — and kept running after handover.
See scope07 / Next step
A free survey, then honest numbers.
Tell us where you are and what you need. We come, we measure, and we quote what the building actually requires.
+91 78881 58812 · Latur, Maharashtra, India